Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13555878

- Product Categories
- Friendly Links
Information Name: | Four Access Controller / Guangzhou Access Controller / 485 four Access Controller |
Published: | 2014-11-10 |
Validity: | 0 |
Specifications: | Tray |
Quantity: | |
Price Description: | |
Detailed Product Description: | M2M-RS602 Network Access Controller is a can simultaneously control two doors open out all credit card access control, which uses internationally accepted standard RS485 communication protocol to connect with the computer, and it adopts the international advanced ARM32-bit processor, integrated high computing speed, stable operation, low power consumption. The controllers are widely used in other institutional units the company offices, schools, banks, telecommunications, electricity, prisons, the armed forces, the pavilion and the like. Features: design features based on ARM32-bit microprocessors 荷兰恩 NXP ARM series 32 high-performance microprocessors, not 51 microcontroller, high integration, high operation speed, stable operation, low power consumption. Massive Flash memory technology capacity non-volatile Flash memory technology, no batteries to maintain the data, information, and never lost. Anti-crash system watchdog circuit automatically detects whether the crash, the chance to die in an instant if intelligent automatic restart, and never crashes. Anti-reverse, anti wrong connection protection power, communications interface comes with protection circuit, a wrong or reversal does not cause damage to the equipment. Lightning protection, surge protection with high-level three mine design, 5000V lightning 50 consecutive times without damage, along with the anti-surge, anti-surge, anti-overvoltage protection. Large load relay output can be controlled in addition to the electric lock more current load can be applied to a variety of access control systems outside the controller system. An external alarm output expansion DI / DO expansion boards to achieve illegal door alarm, duress alarm, intelligent linkage functions. Controller functions in a dedicated access control management software fit, C800 series access controllers only support the general user access commonly used functions, such as: real-time monitoring, electronic maps, real-time photos show run offline, mass storage, time and personnel grouping management, remote to open the door, the door alarm is not turned off for a long time, broke into the police, and other functions. It also supports many professional industrial users such as banking, telecommunications, electricity, prisons, military, pavilions and other industry-specific features, such as: temporary card management, illegal card swipe alarm, duress alarm, fire linkage, joint monitoring, security linkage, antisubmarine back, multi-card door, card + password to open the door, open the door timing and other functions. Function schedule automatic real-time monitoring system, real-time monitoring equipment working status and fault conditions, and management on a computer with a sound and light alarm, alarm interface software can automatically alert administrators. Electronic map function to import the electronic map, and the icon of the door on the map corresponding to a location to display more intuitive and user-friendly real-time monitoring. Area, time and personnel group management and access to the access time to limit the area of ??the cardholder, and the time region are combined to form a packet with the person, the cardholder is assigned to different groups of people, that is, what is realized in the cardholder Time permitting authority to define which areas to enter. Temporary card management feature set someone into effect a few months a few days, a few months a few days the card expires. Before the effective date, the card has not yet entered into force, can not be used; to the commencement date, will take effect automatically use; to the expiration date, the card will automatically void can not be used. After running off the next pass through the software settings, the controller will remember all the permissions and records all the information, even if the computer software and the computer is off, the system can still be normal off running, even if the power information is never lost. Offline card authorization jumper allows the controller goes offline authorization mode, the user only needs to read the card through a card reader controller can authorize the card. Doors normally open normally closed function if some take a long time to open the door, it can be set by software which is normally open, some take a long time to close the door does not want anyone to enter, it can be set to normally closed. Remote control gate function remote control software allows the administrator to any or all doors open and close. If you choose a card alone downstream users just add a few or several people permission to modify, without the need to pass all the permissions again next time, add and modify permissions can be individually downstream. Card + password function the user to enter the correct password to open the door after the credit card. A password can be a card that everyone has their own password. This feature prevents the card is lost after the man picked up the door, increasing the security of the system. For the same door, you can set some people require card + password, some people simply swipe card to get into. The password can be 4-8 digits. This function must use the PIN pad reader. Manually enter the password to open the door function if the user enables this feature, you do not need with a card, simply enter the password, you can open the door, and stores the access records. Each door can be set up 10 password, the password is 4-8 digits fire alarm emergency opening function if the controller receives a signal when the fire switch, the controller automatically opens all doors jurisdiction, to facilitate people to escape. And can start the fire siren and store records of fire alarm record time. DIDO linkage output function control panel has five inputs can be used to access the home button, door switches, infrared sensors, fire sensors; 4 outputs NO, NC mode selectable, can be used to control power locks, alarm, lights and other equipment, the linkage between security subsystems. Forced door alarm forced open the door, which did not pass the legal method (credit card or buttons, etc.) to force open the door or break-ins. System software monitors the interface will prompt the red alarm time and location, and drive the computer speaker reminded duty personnel. If the controller is connected to the alarm output and fire linkage expansion board, you can also spot the drive alarm beeps, deter crime and reminded the security personnel rushed to the scene. This feature requires the installation of door sensor or door sensor feedback signal output with a choice of electric lock and connect to the controller. Door not closed alarm time the door is opened for a long time (how much time can be customized to open the alarm) is not closed, the system software control interface will prompt the red alarm time and location, and drive the computer speaker reminded duty personnel. If the controller is connected to the alarm output and fire linkage expansion board, you can also spot the drive alarm beeps to alert people shut the door. This feature requires the installation of door sensor or door sensor feedback signal output with a choice of electric lock and connect to the controller. You can set how many seconds or until the alarm until the alarm is reset. Duress alarm when a staff member was asked to open the door when coercion, duress staff can enter the password in the password keyboard, the goalkeeper has been opened to try to avoid personal staff injuries by angry criminals, while the total control center monitoring software the interface has been shown that the place has been open duress alarm information and take action. Meanwhile in the control center of the computer speakers will sound an alarm to alert staff on duty prompt attention. Illegal card swipe invalid card swiping alarm called the police. That someone with unauthorized attempts to swipe the card, the system will be red prompt alarm monitoring software interface and drives the computer speakers to remind duty personnel. If the controller is connected to the alarm output and fire linkage expansion board, you can also spot the drive alarm beeps, deter people who live there are ulterior motives, reminding security came. After the anti-passback feature when a user enters credit card, you must exit from the specified credit card to go out, go out after swiping the card again to open the door from the entrance, prohibit a card swipe continuously from one entrance door, effectively preventing the use of a common people cards. The controller not only do the same antisubmarine a back door, from the card into the door, the door must swipe out from this, you can do different doors within the controller anti-passback. There are some two-door interlock requirements specially occasion, a door is not good before, another person is not allowed to enter the door. This function is mainly used for high security requirements of the occasion bank, savings bank treasury, arsenal and so on. Multi-card door has certain occasions you need to enable this feature, which requires a few people at the scene, followed by credit card before opening the door. A personal credit card does not open the door to the scene alone. This function is generally used for bank vaults antique collection site museum. Timed automatic door function the user can set their own electric locks automatically opened and closed. The function for a certain period of time or a lot of people out of very frequent movement of people in and out of the public channel very applicable. As the cell door, the main entrance hall and other administrative work. The system will automatically turn on when power locks staff out frequently, in order to reduce the loss of mechanical devices and prolong life, until personnel access frequency drops, especially at night, the system can automatically power locks closed, with staff required to have access Authorized proximity cards. Technical parameters: Model M2M-RS602 function can control two doors and go out the door card button, or go out into all credit card size 150mm × 120mm power static 60mA, dynamic 135mA Operating temperature -40 to +70 degrees Celsius Operating humidity 10% -85 % maximum number of networked communication RS485 255 can be accessed by the number of two pairs Reader reader input format Wiegand 26 / Wiegand 34 internationally accepted protocol storage capacity of 50,000 users (expandable to 100,000 users), 150,000 incidents Record (expandable to 150 000 event records) |
Admin>>>
You are the 9415 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou, Hong Qin Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 9415 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou, Hong Qin Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility